Technical parameters
Valid working space(W*H*L) | 500mm×500mm×1800mm |
Max.loading weight | 1500kg(The load capacity depends on the product type) |
Temperature | 1600℃(Design maximum temperature) |
1550℃(Actual working temperature) | |
Pumping speed | The vacuum degree can reach 5Pa within 30min after starting the pump. After reaching 5Pa and then pumping for 30min, the ultimate vacuum value reaches 1Pa (within a cold, empty and clean furnace that has been dried before). |
Leakage rate | ≤3Pa/h (stop the pump group operation and start checking after testing the limit vacuum (within a cold, empty and clean furnace that has been dried before). |
Cooling speed | ≤7h(full load,from 1450℃cooling down to 100℃,water temperature≤26℃,2 bar≤water pressure≤3bar) |
Cooling mode | It's equipped with air cooler for rapid cooling that can also cool the furnace. |
Power rating | About 400KVA (The output power can be limited) |
Max.heating rate | 8℃/min (the room temperature rises to 1450℃within a vacuum and empty furnace. 600℃, 1000℃, 1200℃ half-way insulation is allowed). |
Wax yield rate | ≥98%(10kg pure paraffin, argon negative pressure dewaxing. Measured by three times of mean values at most). |
UPS guarantee time | It can power the indicator light and control the furnace during power outage for more than 80 minutes. |
Atmosphere Uniformity in sintering zone | Positive pressure or negative pressure degreasing integration sintering uniformity: furnace control piece (YC40 or YG6 particles) and paraffin forming agent are evenly distributed on the graphite boat. *(The buyer shall provide the furnace control piece and program, and the seller shall confirm.) Alnico: test cobalt magnetic field after dewaxing, deviation range: ≤±0.3%; Coercive force: deviation range: ≤± 0.4kA /M. The uniformity of furnace temperature is the standard of the uniformity of coercive force. |
![]() |